TECHNICAL SPECIFICATIONS40,000 Watt Experimental Coil PRIME POWER REQUIREMENTS - 45kVA Main Transformers and Rotary Gap - 480VAC, 3PH, 50A, 60Hz, ~0.8PF Control System - 120VAC, 1PH, 10A, 60Hz
HVDC SUPPLY DC Output - 18,000V (star configuration), 10,500V (delta configuration) Charging Reactor - 5H, 3A, 26kVDC Final primary charge voltage - 35kVDC (max)
PRIMARY DRIVE CIRCUIT Cpri = 0.195µF, nominal Lpri = 36µH nominal, 35 to 36.7uH range w/ Litz tuner Zpri = 14 ohms, nominal Ipri (pk) = 2500A Primary Switch - 4 gap series rotary, adjustable speed to 360 BPS
SECONDARY COIL TOWER STRUCTURE Coilform - 43" x 120", 375 turns of #8 AWG 'locomotive' wire Lsec = 0.051H Fsec = 62kHz (w/65" toroidal electrode), 72kHz (no electrode) Top electrode - 65" dia sphere, Al 6061 finite element cage construction Total tower weight - 2100 lbs Total tower height - 15' 2" |